Complete Fire Protection
|
|
|
|
Britannia Fire & Security Ltd. are one of the UK's leading suppliers, installers and maintainers of fire alarm systems.
|
|
|
|
Choose from latest state-of-art technologies for all commercial, industrial or domestic applications.
|
|
|
| Complete fire protection by BAFE SP203 company accredited, also GENT 24 Integrator. |
|
|
|
| Addressable Detection |
|
| The concept of addressable detection is well established, and the ability to interrogate each device ensures that the precise location of a change of status can be identified. Digital Addressable systems enhance this capability, by returning a numeric value which directly relates to the environmental conditions in the immediate vicinity of the detector. |
|
|
|
|
| This ensures that the detector and control panel can indicate an early detection of a Fire condition, with fewer unwanted alarms. These systems offer many benefits, including a Pre-alarm facility to warn of an increase in smoke or heat, before triggering a full alarm, and analysis of the returned values can identify faults, allowing predictive maintenance. |
| Features Fire Alarm Systems, Fire Alarm Systems, Fire Alarm Systems |
 |
1 or 2 detection loops - The capacity of the panel can meet the needs of each installation, for economy. A second loop can be added at any time.
|
 |
30 Fire and Fault indicators - The current standards demand that panels have the ability to display ALL zones in alarm simultaneously.
|
 |
Extensive cause-and-effect capability - By including day/night setting, coincidence operation, and 'non-fire' inputs, there are few applications which cannot be handled by the standard system.
|
 |
Fast and easy Start-up Wizard - The control panel leads the installer through a series of questions, resulting in faster commissioning with fewer errors.
|
 |
Option integral thermal printer - If a hard-copy record is a requirement, the fast, reliable printer option can be specified.
|
 |
5 Programmable outputs - Any of which can be independently set as sounder or volt-free by the installer, for maximum flexibility in system design. |
 |
Programmable inputs - Any loop input can be used to function as a programmable Isolate, Silence, Day/Night or Class Change signal (or just be a fire alarm). |
 |
Non-fire signals - An input can be set to perform a cause/effect action, without lighting the Fire lamp, or zone, nor operating sounders or other Fire outputs. |
|
|
|
|
| ZP3 Analogue Addressable Fire Alarm Systems |
| The Ziton ZP3 fire detection system is an advanced analogue addressable system that offers outstanding performance, proven in numerous installations worldwide. It is a programmable, software based system that provides early warning of fire or smoke. The system is approved to various international standards. This includes Loss Prevention Certification Board (LPCB) UK certification to the EN54 (Parts 2 and 4) international standard. |
|
|
|
|
| A full range of high-performance analogue addressable fire sensors, including single, and combination and multisensors are supported. Adjustable sensitivity, alarm verification and pre-alarm provide early warning without false alarms. The ZP "active" protocol provides proven reliability. Automatic checking of wiring and sensors, corrupt data detection and disconnection of faulty zones is supported. Built-in diagnostics improves the level of maintenance and reduces cost. Included are remote diagnostic support (optional), sensor testing, status reports and contamination and near service reports. |
|
|
|
|
ZP732-2 Combination Smoke & Thermal/Sensor PS1245.4
|
| Designed to provide the earliest response to a wide range of fire types. The ZP732-2 sensor combines optical smoke sensing and thermal monitoring to provide accurate warning of fire. Individual software monitoring of each element measures actual smoke levels, in addition to temperature rates of rise. Smoke sensing can be isolated for areas where ambient smoke may exist at certain times of the day, or used on a day night basis in premises where heat only is required whilst the building is occupied. |
| Temperature response meets the requirements of European Standard, EN 54 Part 5. (programmable to Grade 1 or Grade 3), with smoke sensitivity complying with EN 54 Part 7. The sensor is approved by several international approval bodies including the Loss Prevention Certification Board (LPCB). |
|
|
|
|
|
|
|
| Gent Vigilon Compact Fire Alarm Systems |
| Introducing Vigilon Compact the latest addition to the well respected Gent Vigilon family of analogue fire detection and alarm systems. |
|
| Vigilon Compact 1-2 loop panels offer small to medium sized building owners the unique system functionality of Vigilon with the very best in control panel aesthetics - stainless steel door options are available to provide a discreet and luxurious feel in upmarket office environments. |
|
|
|
 |
|
The introduction of innovative design features into this panel means that the wall space needed to mount the panel is now 60% smaller than a standard Vigilon installation. |
|
| Vigilon Compact analogue addressable panels fully comply with EN54:Parts 2 and 4 and can be specified with 1 or 2 detection loops, each capable of accommodating 200 devices comprising of repeat panels, interfaces, manual call points, sensors and sounders. |
|
|
| Conventional Systems |
|
| The Britannia Range of fire alarm control panels is designed to provide small to medium sized buildings with completely reliable fire protection and is designed to comply with the requirements of EN54. This panel has been designed to work with the Apollo '2 wire' Alarmsense range of detectors, call points and sounders. |
|
|
|
|
| Specifications Fire Alarm Systems, Fire Alarm Systems, Fire Alarm Systems |
 |
2-12 Zone - 300mm (height) x 350mm (wide) x 85mm (deep).
|
 |
Metal cabinet with lift off front door with knockout at top and bottom.
|
 |
Fitted with lock and enable key.
|
 |
1.5 amps for a maximum of 2 x 7AH.
|
|
| For more details on Conventional Fire Alarm Systems, or to discuss your specific requirements please telephone or complete our contact us form. |
|
|
|
| Radio Systems |
|
| The installation of wired alarm systems cause considerable disruption to both the fabric of the building and working environment. Any subsequent changes or modifications would be extremely expensive. |
|
| Radio Systems give that extra degree of freedom in design and are now considered as an equal to conventional systems. |
|
|
|
|
| Radio signalling of vital data between Detectors, Controllers and warning devices has been successfully integrated into the Fire Alarm industry for over a decade. During that time there have been many improvements to Radio Fire Alarm Systems which are now in use in historic buildings, commercial properties, hospitals, hotels, schools and industrial premises. |
| More than 50,000 systems have been installed throughout the UK in bank premises, museums, schools, retail stores and other applications where unobtrusive security is of vital importance. |
|
|
|
| ZLSS1 LaserSence 25, High Sensitivity Smoke Detector PS1837.1 |
 |
|
|
LaserSense 25 is a high sensitivity smoke sensor designed to give the earliest possible warning of fire.
|
|
|
|
Smoke from the protected area is drawn through the LaserSense detector and analysed twice every second by a laser pulse. Over a period of 24 hours smoke pollution distribution in the protected environment is compiled and a databank created.
|
|
|
| ZLSS2 LaserSence 100, High Sensitivity Smoke Detector PS1838.1 |
| LaserSense 100 is a high sensitivity smoke sensor designed to give the earliest possible warning of fire. |
|
| Smoke from the protected area is drawn through the LaserSense detector and analysed twice every second by a laser pulse. Over a period of 24 hours smoke pollution distribution in the protected environment is compiled and a databank created. |
|
|
|
|
|
|
|
|
Fire Alarm Systems Brochures Fire Alarm Systems
|
|